Repairing Cracks at Junctions of Walls

Method Statement

1. Cut a slot into the horizontal mortar joint using a wall chaser
2. Clean the slot with a vacuum and thoroughly flush with water
3. Insert a bead of Bond Flex into the back of the slot using a Bond Flex gun kit
4. Push the Bar Flex into the Bond Flex at the back of the slot
5. Insert a bead of Bond Flex over the exposed Bar Flex and iron into the slot using a finger trowel
6. Point of fill the joint and leave ready for any decoration

Guidelines

A. Depth of slot is 35 mm
B. Bar Flex to be installed a minimum of 500 mm each side of the crack
C. Vertical spacing of crack stitches is 300 mm (4 brick courses)